AT&T PagePac Plus AmpliCenter Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Wzmacniacze audio AT&T PagePac Plus AmpliCenter. AT&T PagePac Plus AmpliCenter Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 92
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
AT&T
Page Pac
®
Plus Paging
Controller
Programming and Operation Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 91 92

Podsumowanie treści

Strona 1 - AT&T

AT&TPage Pac®Plus PagingControllerProgramming and Operation Guide

Strona 2 - Support Telephone Numbers

Security ProtectionAn Access Password and a Programming Password can easily beestablished for the PagePac Plus system. Both passwords are operativefor

Strona 3 - Contents

Figure 1-1. PagePac Plus System ComponentsOverview 1-5

Strona 4

Managing the SystemInstalling System HardwarePlease refer to the Installation Guide for complete instructions for installingthe PagePac Plus Unit, Amp

Strona 5 - How to Use This Guide

Daily OperationDepending on how your system is set up, you may need to oversee someof the system’s daily operation. For example, if your system isprog

Strona 6 - Reference Materials

Factory-Set Default InputsThe PagePac Plus Control Unit has five factory-set default inputs that areactive on a priority basis. These five, in order o

Strona 7 - Overview

Eight Primary Paging ZonesNOTE: The Zone Option The PagePac Plus Control Unit has eight onboard zones. All eight zonesswitches, both on the PagePaccan

Strona 8 - ■ Connectors on Rear

Three Output TypesThe PagePac Plus Control Unit has three audio outputs, with the levelcontrolled by an automatic gain control (AGC) to ensure excelle

Strona 9 - About PagePac Plus

Whether the PagePac Plus system is configured as a constant-voltagedistribution system, a controller system, or as a hybrid system, has nobearing on p

Strona 10 - Security Protection

Amplicenter:Controller Unit:Zone Expansion Unit:AC Power in; 110VAC at 60 Hz or 220VAC at 50 HzOdBm out, control and audio for remote amplifierDC Powe

Strona 11 - Overview 1-5

Figure 1-2. Amplicenter, Controller, and Zone Expansion Unit Back PanelsOverview 1-13

Strona 12 - Solving Problems

Copyright 1993 AT&TAll Rights ReservedWritten/Printed in U.S.A.AT&T 463-248-2040II722580-002Issue 3, May 1993NoticeEvery effort was made to en

Strona 13 - Daily Operation

Connectors on RearYou have access to controls and connections on the back panel, which iscovered with a removable lid (see figure 1-2). For instructio

Strona 14 - Factory-Set Default Inputs

Interface ConsiderationsThe hardware installation configuration may have these impacts onprogramming and use of the PagePac Plus system:Setting correc

Strona 15 - 48 Expansion Zones

Zone MapDescription of ZonePhysical Zone NumberPhysical Zone CodeNOTE: If an ALIAS number isassigned to any zone, ALIASnumbers must be assigned toALL

Strona 16 - Hardware Configuration

Table 1-1. Zone Map ExampleDescription of ZonePhysicalZoneNumberPhysicalZoneCodeALIAS*ZoneNumberInput (1 or 2) orOutputWarehouse Area PagingZone 20221

Strona 17 - Back Panel Nomenclature

Table 1-2. Zone MapDescription of ZonePhysicalZoneNumberPhysicalZoneCodeALIAS*ZoneNumberInput (1 or 2) orOutputZone 202Zone 303Zone 404Zone 505Zone 60

Strona 18 - Zone Expansion Unit:

Table 1-2. Zone Map (Continuation Page 1)Description of ZonePhysicalZoneNumberPhysicalZoneNumberALIAS*ZoneNumberInput (1 or 2) orOutputZones 9 thru 2

Strona 19 - Overview 1-13

Table 1-2. Zone Map (Continuation Page 2)Description of ZonePhysicalzonenumberPhysicalZoneCodeALIAS*ZoneNumberInput (1 or 2) orOutputZones 25 thru 40

Strona 20 - Connectors on Rear

Table 1-2. Zone Map (Continuation Page 3)Description of ZonePhysicalZoneNumberPhysicalZoneCodeALIAS*ZoneNumberInput (1 or 2) orOutputZones 41 thru 56

Strona 21 - Interface Considerations

Zone Configuration TablesThe Zone Configuration Table consists of two parts, one for input zonesand another for output zones. The table is to be fille

Strona 22 - Zone Map

Table 1-4. Zone Configuration TableInput ZonesDescription of InputZonePriorityLevel 1or 2PhysicalZoneCodeSelectTone 1-7RouteTone toZoneAudioEnable0-2A

Strona 23 - Table 1-1. Zone Map Example

ContentsAbout This Guidevii How to Use This Guidevii Getting Startedviii How to Comment on This Guideviii Product Ordering Informationviii Reference M

Strona 24 - 1-18 Overview

Programming The Controller2ContentsIntroduction Programming by Touchtone Telephone Programming by PCSoftware Configuration—Overview Zone Group versus

Strona 25 - (Continuation Page 1)

Computer MonitorInput Computer MonitorGeneral Zone / Group Configurations OverviewCOPY CommandZone Map Option—Assigning ALlAS Num

Strona 26 - 1-20 Overview

IntroductionThe operation of the PagePac Plus Controller can be customized to meetthe requirements of your business. It can be programmed in either of

Strona 27 - (Continuation Page 3)

Software Configuration—OverviewThe PagePac Plus Controller is pre-programmed with certain defaultvalues when shipped, However, not all paging systems

Strona 28 - Zone Configuration Tables

Programming Options and InstructionsCAUTION:The Zone Option switches must be set before the PagePac Plus system ispowered up, and therefore before pro

Strona 29 - Input Zones

Reset to Factory DefaultsThis system option allows you to "undo" all system changes you havemade, in order to "start over." This R

Strona 30 - Programming The Controller

Define Length of ALIAS NumbersThis system option allows you to set the length (2, 3, or 4 digits) of theALlAS number field. The default is 2 digits. I

Strona 31 - Error Tones

Connect PasswordThis feature will not become active until the first time you enter apassword, via the programming mode. The factory default is NOpassw

Strona 32 - Programming by PC

Programming StepsFirst access the PagePac Plus system and enter the programming modeby pressing [ * ] [ * ] and entering your Programming password (if

Strona 33 - At Power Up

Programming PasswordEstablishing a Programming password will restrict access to theprogramming mode of the PagePac Plus paging system. It isrecommende

Strona 34 - Enter Programming Mode

3.Operation3-1 Power Up3-2System Administrator3-2End User3-2User Quick Reference Card3-4A.Application NotesA-1IN.IndexIN-1iv

Strona 35 - Reset to Factory Defaults

Forgot the Password?In the event that either or both the connect password and programmingpassword are forgotten, it will be necessary to call the Harr

Strona 36 - Programming Steps

Pre-Announcement Tone ON/OFFThe choice for this parameter is ON/OFF, with the default setting ON.This tone is very similar to the initial talk-back wa

Strona 37 - Connect Password

Talk-Back Warning ToneThis tone is intended to alert a person that their conversation is beingmonitored through the paging system loudspeaker. If Talk

Strona 38

VOX Disconnect TimingThis is a loop supervision parameter for the station mode of the TelephoneInterface. The PagePac Plus unit will return to an ON H

Strona 39 - Programming Password

Computer MonitorComputer MonitorModeNOTE: Since the default optionis the ONLY option, there is noneed to program this.Programming StepsNOTE: For Zone

Strona 40 - Confirmation Tone ON/OFF

Input Computer MonitorProgramming StepsThis option turns ON or OFF the inputs of Attendant Access, TelephoneAccess, and Night Bell to be recorded and

Strona 41 - Pre-Announcement Tone ON/OFF

COPY CommandThe COPY command can be used to copy the configuration of a zone thathas already been optioned, to one or more additional zones. This save

Strona 42 - Talk-Back Warning Tone

Zone Map Option—Assigning ALIAS NumbersNOTE: Before doing thisoption, you MUST do "DefineLength of ALIAS Numbers"above. (see table 2-2)NOTE:

Strona 43 - VOX Disconnect Timing

Type of Zone: Input or OutputThe choices here are INPUT #1, INPUT #2, and OUTPUT. Be sure themanually selectable Zone Option switch on the rear of the

Strona 44 - Computer Monitor

Input Priority ArrangementNOTE: These priorities cannotbe rearranged.Also, if you select more than onezone to be inputs of the samelevel (Input 1, fo

Strona 45 - Input Computer Monitor

About This GuideREAD THIS GUIDE FIRST, before using the Installation Guide to installPagePac Pius equipment. You will need to complete the Zone Map (

Strona 46 - COPY Command

Zone MonitorThis option selects a device to be connected to the RS-232 port, acomputer monitor for logging of all zone or group zone paging activity.T

Strona 47

Zone GroupingThis option allows you to select a group of zones to be paged at the sametime, The number of zone groups that can be formulated is eight;

Strona 48 - Type of Zone: Input or Output

Output Zone/Group Confimations OverviewThese options apply to zones or groups already configured as outputs (see"Type of Zone," above). All

Strona 49 - Input Priority Arrangement

Programming StepsFirst access the PagePac Plus system and enter the programming modeby pressing [ * ] [ * ] and entering your Programming password (if

Strona 50 - Zone Monitor

Page EnableProgramming StepsThis output zone parameter enables paging for a selected output zone orzone group. The choice for this selection is YES/NO

Strona 51 - Zone Grouping

Music EnableThis is an individual zone output parameter, that enables backgroundmusic to be broadcast to a selected output zone (in the absence of ahi

Strona 52 - Type of Output

Talk-Back EnableThis is a zone output parameter that enables talk-back capability for aselected output zone or group. The choice is YES/NO, with the d

Strona 53

Night Bell EnableThis is an individual zone output parameter. The choice is YES/NO withthe default being NO. With this parameter set to YES, night bel

Strona 54 - Page Enable

Pass DTMF to the OutputThis zone output option enables the Touchtone telephone keypad tones(DTMF) to be passed through the PagePac Pius Controller and

Strona 55 - Music Enable

Programming StepsFirst access the PagePac Plus system and enter the programming modeby pressing [ * ] [ * ] and entering your Programming password (if

Strona 56 - 7 ] [ 7 ] and

Solving Problems. Should any problem arise that requires technicalassistance beyond the information provided in this guide, call:AT&T Technical

Strona 57 - Night Bell Enable

Input Zone / Group Options OverviewThese options apply to zones or groups already configured as inputs (see"Type of Zone," above). These opt

Strona 58 - Pass DTMF to the Output

To verify the tone option for a given input zone, dial [ 9 ] [ 3 ] and repeatsteps 2 and 3 above.These actions are summarized in table 2-22. The diffe

Strona 59

Tone RoutingProgramming StepsWhatever zones are selected here will receive the tone selected in theprevious option, "Tone Selection."For exa

Strona 60 - Tone Selection

Audio Source EnableThe primary use for this feature is to allow the PagePac Plus to be usedfor door service. If optioned, whenever a selected zone is

Strona 61 - 9 ] [ 3 ] and repeat

Audio RoutingDoor ServiceProgramming StepsIf optioned, whenever a selected input zone with "Audio Source Enabled"is active, the audio source

Strona 62 - Tone Routing

Error TonesHear error tonewhen dialing a zoneALIAS numberError tone receivedwhen programminga zone or groupThe Error Tone is heard over the phone rece

Strona 63 - Audio Source Enable

Programming Quick Reference ChartTo Enter the(1) dial the PagePac Plus system access extensionProgramming Mode(2) enter the connect password (if any)(

Strona 64 - Audio Routing

Chart 2. General Zone / Group ConfigurationsFeatureMode Option/VerifyDialListenForZone/GroupSelectionListenForChoose OptionListenForDefaultZone MapTo

Strona 65

Chart 3. Output Zone / Group ConfigurationsFeatureMode Option/VerifyDialListenForZone/GroupSelectionListenForChoose OptionListenForDefaultType ofTo Se

Strona 66 - Programming Mode

Chart 4. Input Zone / Group ConfigurationsFeatureMode Option/VerifyDialListenForZone/GroupSelectionListenForChoose OptionListenForDefaultActivateTone

Strona 67

Overview1ContentsAbout PagePac PlusManaging the System Installing System HardwareChanging System SettingsTraining Co-WorkersSolving ProblemsDaily

Strona 68

Operation3ContentsPower UpSystem AdministratorEnd User Using Telephone to Make a Voice Page Using Telephone to Respond to Doorbell ToneUser Quic

Strona 69 - The Copy Command

Power UPWhen the PagePal Plus Controller is first powered up, it polls the zones todetermine how many (if any) zone expansion modules are present. (Th

Strona 70 - Operation

Using Telephone to Respond to Doorbell ToneWithin 10 SecondsIf you pick up your telephone and access the paging system within 10seconds of the soundin

Strona 71 - End User

User Quick Reference CardRemove the blank User Quick Reference Card (opposite page) and fill itout o reflect your paging system. Make copies and distr

Strona 72 - Unlock the Door

PAGING SYSTEM QUICK REFERENCE CARDPaging System Access by(1) Dial the PagePac Plus system access extension.Telephone(2) Enter the Connect password (if

Strona 73 - User Quick Reference Card

AApplication NotesNight BellThere are two different Night Bell connections possible with the PagePacPius Controller. These are illustrated in figure A

Strona 74

Figure A-l. Night Bell InterfacesA-2 Application Notes

Strona 75

Background MusicIs a music source connected to your PagePac Plus Ampiicenter? Whichzones do you wish background music to be heard in? You can adjust t

Strona 76 - A-2 Application Notes

Figure A-2. Music InterfacesA-4 Application Notes

Strona 77 - Background Music

Door ControlVisitor PressesFigure A-3 illustrates door control interfaces.DoorbellWhen a visitor presses the doorbell of a security door, a contact-cl

Strona 78 - A-4 Application Notes

Hardware ConfigurationIndicators and Connectors LED Indicators Back Panel Nomenclature Connectors on RearPowerInterface ConsiderationsZone Ma

Strona 79 - Door Control

Figure A-3. Door Control InterfacesA-6 Application Notes

Strona 80 - A-6 Application Notes

Alarm System InputFigure A-4 illustrates a typical alarm system interface.Program the alarm system input as a contact-closure input, resulting in awar

Strona 81 - Alarm System Input

Figure A-4. Alarm System InterfaceA-8 Application Notes

Strona 82 - A-8 Application Notes

TalkbackAll speakers in a zone will be two-way speakers, if talkback has beenenabled for a zone. Therefore all speakers in the talkback zone will pick

Strona 83 - Talkback

Figure A-5. System with Talk-BackA-10 Application Notes

Strona 84 - A-10 Application Notes

Computer Monitor Paging LogIs a PC computer connected to the RS-232 port of the PagePac PlusController for the purpose of logging paging activities? I

Strona 85 - Computer Monitor Paging Log

Figure A-6. Computer Monitor Logging InterfaceA-12 Application Notes

Strona 86 - A-12 Application Notes

Connecting Additional PagePac Plus Controllers or RemoteAmplifiersWhen additional PagePac Plus Controller(s) or other ancillary devices aredaisy-chain

Strona 87 - Amplifiers

Figure A-7. System with Additional Controller / Remote AmplifierA-14 Application Notes

Strona 88 - A-14 Application Notes

IndexAAbout this guidei-viiActivate tone via an input closure2-40Additional controllerDiagramA-14Alarm system inputA-7Alarm system interfaceDiagram A-

Strona 89

About PagePac PlusTelephone Access andTalk-backSecurity Door Controland Night BellAutomatic MessageLoggingPagePac PlusAmplicenterZone Expansion UnitsE

Strona 90 - IN-2 Index

HHardwareConfigurationInstallationHow to use this guideIIndicatorsInput #1Input #2Input computer monitorInput priorityInstallationInterface considerat

Strona 91

Quick reference chartTalkbackTone mutingTouchtone telephoneZone groupingProgramming memoryProgramming passwordQQuick reference chartRReference materia

Strona 92

©1993 AT&TAll rights reservedPrinted in U.S.AAT&T 463-248-2040II722580-002Issue 3, May 1993Graphics © AT&T 1988

Komentarze do niniejszej Instrukcji

Brak uwag