AT&T DEFINITY 2500 series Instrukcja Obsługi Strona 194

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 223
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 193
UPGRADES AND ADDITIONS
System 75 XE Upgrade to DEFINITY Generic 1 EPN Without
Duplication
The System 75 XE is upgraded to the EPN Cabinet Without Duplication as follows:
Replace the Control Cabinet J58890G-1 with an Expansion Control Cabinet J58890N-1
Replace the TDM cables with WP91716 L3 TDM cables if required
Add and restructure port circuit packs
System 75 XE Upgrade to DEFINITY Generic 1 EPN With
Duplication
The System 75 Single-Carrier Cabinet is upgraded to the EPN cabinet With Duplication as fol-
lows:
Replace the Control Cabinet J58890G-1 with an Expansion Control Cabinet J58890N-1
Replace the TDM cables with WP91716 L3 TDM cables if required
Add and restructure port circuit packs
Add an Expansion Interface circuit pack to the first and second port cabinets
Add two TN768 Tone Clock circuit packs (one in the first cabinet and one in the second
cabinet)
Two TN776 Expansion Interface circuit packs are needed in the PPN cabinet. Two fiber links are
required to connect the Expansion Interface circuit packs.
184
Przeglądanie stron 193
1 2 ... 189 190 191 192 193 194 195 196 197 198 199 ... 222 223

Komentarze do niniejszej Instrukcji